BOARD LET-OFF TOYOTA JAT-610 Air Jet Loom Part HL1152 YHE-0302 J9202-10001-00 Warp Tension
Product Overview
Let-off board for Toyota JAT-600 / JAT-610 / JAT-710 air jet looms. Original part number J9202-10001-00, our item code YHE-0302, reference HL1152.
Warp tension is set by the let-off and taken up by the take-up, and the two systems share the same symptom list. That is why so many let-off boards are replaced without solving the problem: the fault was in the tension roller, the brake or the take-up gearbox all along. The table below is the check order our engineers use before a board is ordered.
Symptom Check Before Replacing the Board
| Symptom | Check first | Then |
|---|---|---|
| Warp streaks repeating at fixed spacing | Tension roller and guide condition | Tension setting against style sheet |
| Tension falls as the beam runs down | Beam diameter values entered | Tension sensor signal |
| Loose warp after a loom stop | Let-off brake and gearbox backlash | Board output to the motor |
| Motor runs but warp does not advance | Coupling and gearbox | Motor and board output |
| Tension alarm without visible defect | Sensor wiring and plug | Board input channel |
If every item in the second and third column checks out, the board is the remaining suspect - and the replacement should solve it on the first attempt.
Applications & Compatibility
- Machine reference: Toyota JAT-600 / JAT-610 / JAT-710
- Alternative model reference: JAT810
- Original part number: J9202-10001-00
- Our item code: YHE-0302
- Reference: HL1152
Send the marking from your old board with the enquiry. Let-off hardware changed across the series, and the number quoted here must match what is fitted.
Quality Standard
- Board built to the original circuit, so the sensing input and motor terminals are unchanged.
- Input conditioning checked for drift; output stage load tested on the bench.
- Control response verified against a simulated tension signal before packing.
- Terminal blocks and connector pins inspected for plating and secure seating.
- Anti-static packaging with reference label; firmware version noted where relevant.
- Warranty against manufacturing defects, assessed case by case; damage from wrong supply voltage, short circuits or static discharge during handling is not covered.

Specifications
| Product | Board, let-off |
| Original Part Number | J9202-10001-00 |
| Item Code | YHE-0302 |
| Reference | HL1152 |
| Model | JAT710 / JAT810 |
| Machine | JAT-600 / JAT-610 / JAT-710 |
| Function | Let-off motor drive with tension feedback |
| Testing | Input drift and output load test |
| HS Code | 8448499000 |
| Place of Origin | Shanghai, China |
Order & Shipping Information
- Minimum order quantity: 1 piece.
- Sample order is acceptable for quality evaluation.
- Stock items ship within 5 working days after payment confirmation.
- Anti-static bag and foam protection in a neutral export carton.
- Shipping option: DHL / FedEx / UPS express, air freight, sea freight.
- Complete export documents including commercial invoice and packing list will be supplied.
- We ship worldwide to textile markets across Southeast Asia, Central Asia, South America, North America and Europe.

Frequently Asked Questions
Q1: Why do let-off and take-up faults look the same?
Both systems control the same variable - warp tension. A take-up fault changes the tension the let-off tries to correct, so the visible defect is identical.
Q2: How do I separate a let-off fault from a take-up fault?
Watch the tension roller during running. If it moves constantly to compensate, the take-up side or the brake is suspect; if the arm is stable and tension is still wrong, look at the let-off.
Q3: Can a worn tension roller damage a new board?
Not directly, but it will keep the tension wrong after a replacement, which is why the mechanical check comes first.
Q4: Is a spare let-off board worth keeping?
Yes for a department of ten or more looms. Let-off faults stop production quietly through quality losses rather than through a hard stop.
Q5: How is the warranty handled?
Manufacturing defects are covered case by case. Damage from wrong supply voltage, short circuits or static discharge is excluded.
Send your inquiry directly to us