BOARD MAIN I/O TOYOTA JAT-610 Air Jet Loom Spare Part HL1156 YHE-0306 J9201-21020-00 B2
Product Overview
Main I/O board for Toyota JAT-610 / JAT-710 air jet looms. Original part number J9201-21020-00 B2, our item code YHE-0306, reference HL1156.
This board is where the CPU meets the loom. Every stop sensor, every solenoid and every valve passes through it as an input or an output channel. When a channel fails, the loom keeps weaving - only one function disappears. That is what makes I/O faults hard to catch: the machine looks healthy, yet one pick, one nozzle or one stop motion no longer responds.
Applications & Compatibility
- Machine reference: JAT-610 / JAT-710
- Alternative model reference: JAT710 / JAT810
- Original part number: J9201-21020-00 B2
- Board version: B2
- Our item code: YHE-0306
- Reference: HL1156
The version suffix B2 is part of the number and must match. Boards of this family look alike across versions but differ in channel assignment.
Diagnosing a Single Dead Channel
- Confirm it is one function only - if two unrelated functions fail together, suspect the common supply or the board connector, not two channels.
- Swap the sensor or solenoid first - a dead valve coil and a dead output channel read the same on the panel.
- Check the plug and pin - a backed-out pin at the board connector imitates a failed channel exactly.
- Use the I/O monitor - most versions show channel state on a service screen; watch it while the function is triggered.
Keep a note of which channel drives which function for each loom. Two identical looms can be wired differently, and a channel map turns a half-day search into a ten-minute check.
Quality Standard
- Board built to the B2 version, with inputs and outputs assigned to the original channel plan.
- Every input channel tested individually with a simulated sensor signal.
- Every output channel load tested, with current draw checked against the rated value.
- Opto-isolation between field wiring and logic side verified on the bench.
- Connector seating and terminal plating inspected; anti-static packaging with version label.
- Warranty against manufacturing defects, assessed case by case; damage from shorted solenoids, wrong supply voltage or static discharge during handling is not covered.

Specifications
| Product | Board, main I/O |
| Version | B2 |
| Original Part Number | J9201-21020-00 B2 |
| Item Code | YHE-0306 |
| Reference | HL1156 |
| Model | JAT710 / JAT810 |
| Machine | JAT-610 / JAT-710 |
| Function | Sensor inputs and solenoid / valve outputs |
| Testing | Channel-by-channel input and output test |
| HS Code | 8448499000 |
| Place of Origin | Shanghai, China |
Order & Shipping Information
- Minimum order quantity: 1 piece.
- Sample order is acceptable for quality evaluation.
- Stock items ship within 5 working days after payment confirmation.
- Anti-static bag and foam protection in a neutral export carton.
- Shipping option: DHL / FedEx / UPS express, air freight, sea freight.
- Complete export documents including commercial invoice and packing list will be supplied.
- We ship worldwide to textile markets across Southeast Asia, Central Asia, South America, North America and Europe.

Frequently Asked Questions
Q1: One function stopped but the loom runs fine. Is the board the cause?
It can be, since a single dead channel does not affect the rest. Check the sensor or solenoid first, then the plug, then the channel.
Q2: Two unrelated functions failed at once. What does that mean?
Look for a shared cause: supply voltage, a common connector, or moisture in the cabinet. That pattern is rarely two separate channel failures.
Q3: How can I tell a dead output from a dead solenoid?
Measure the coil resistance at the plug. A good coil with no response at the output points to the board.
Q4: Does the B2 version matter?
Yes. Channel assignment differs between versions, so a board of another version can leave functions dead even though it fits the connector.
Q5: How is the warranty handled?
Manufacturing defects are covered case by case. Damage from shorted solenoids, wrong supply voltage or static discharge is excluded.