logo

BOARD MAIN I/O TOYOTA JAT-610 Air Jet Loom Spare Part HL1156 YHE-0306 J9201-21020-00 B2

Place of Origin: Shanghai, China
Brand Name: Y&H China
Certification: Good Quality
Model Number: JAT710/810
Product Details
Place of Origin:
Shanghai, China
Brand Name:
Y&H China
Certification:
Good Quality
Model Number:
JAT710/810
Minimum Order Quantity:
1 Piece
Price:
Request a Quote
Standard Packaging:
Anti-static bag and foam protection in neutral export carton
Delivery Time:
5 working days for stock items
Payment Terms:
L/C, D/A, D/P, T/T
Specifications
Item Code:
YHE-0306
Original Part Number:
J9201-21020-00 B2
Version:
B2
Reference:
HL1156
Model:
JAT710 / JAT810
Machine:
JAT-610 / JAT-710
Product Type:
Board, Main I/O
Function:
Sensor Inputs And Solenoid / Valve Outputs
Testing:
Channel-by-channel Input And Output Test
Use:
Toyota JAT-610 / JAT-710 Air Jet Looms
HS Code:
8448499000
Service:
24-Hour Online Service
Video Outgoing-Inspection:
Provided
Warranty:
Case-by-case
Key Markets:
Southeast Asia, Central Asia, South America, North America, Europe
Shipping:
Express (DHL/FedEx/UPS) / Sea Freight / Air Freight
Brand Name:
Y&H China
Product Description

Product Overview

Main I/O board for Toyota JAT-610 / JAT-710 air jet looms. Original part number J9201-21020-00 B2, our item code YHE-0306, reference HL1156.

This board is where the CPU meets the loom. Every stop sensor, every solenoid and every valve passes through it as an input or an output channel. When a channel fails, the loom keeps weaving - only one function disappears. That is what makes I/O faults hard to catch: the machine looks healthy, yet one pick, one nozzle or one stop motion no longer responds.

Applications & Compatibility

  • Machine reference: JAT-610 / JAT-710
  • Alternative model reference: JAT710 / JAT810
  • Original part number: J9201-21020-00 B2
  • Board version: B2
  • Our item code: YHE-0306
  • Reference: HL1156

The version suffix B2 is part of the number and must match. Boards of this family look alike across versions but differ in channel assignment.

Diagnosing a Single Dead Channel

  • Confirm it is one function only - if two unrelated functions fail together, suspect the common supply or the board connector, not two channels.
  • Swap the sensor or solenoid first - a dead valve coil and a dead output channel read the same on the panel.
  • Check the plug and pin - a backed-out pin at the board connector imitates a failed channel exactly.
  • Use the I/O monitor - most versions show channel state on a service screen; watch it while the function is triggered.

Keep a note of which channel drives which function for each loom. Two identical looms can be wired differently, and a channel map turns a half-day search into a ten-minute check.

Quality Standard

  • Board built to the B2 version, with inputs and outputs assigned to the original channel plan.
  • Every input channel tested individually with a simulated sensor signal.
  • Every output channel load tested, with current draw checked against the rated value.
  • Opto-isolation between field wiring and logic side verified on the bench.
  • Connector seating and terminal plating inspected; anti-static packaging with version label.
  • Warranty against manufacturing defects, assessed case by case; damage from shorted solenoids, wrong supply voltage or static discharge during handling is not covered.

Air jet loom spare part quality inspection and stability test

Specifications

ProductBoard, main I/O
VersionB2
Original Part NumberJ9201-21020-00 B2
Item CodeYHE-0306
ReferenceHL1156
ModelJAT710 / JAT810
MachineJAT-610 / JAT-710
FunctionSensor inputs and solenoid / valve outputs
TestingChannel-by-channel input and output test
HS Code8448499000
Place of OriginShanghai, China

Order & Shipping Information

  • Minimum order quantity: 1 piece.
  • Sample order is acceptable for quality evaluation.
  • Stock items ship within 5 working days after payment confirmation.
  • Anti-static bag and foam protection in a neutral export carton.
  • Shipping option: DHL / FedEx / UPS express, air freight, sea freight.
  • Complete export documents including commercial invoice and packing list will be supplied.
  • We ship worldwide to textile markets across Southeast Asia, Central Asia, South America, North America and Europe.

Air jet loom spare part export packing and shipping

Frequently Asked Questions

Q1: One function stopped but the loom runs fine. Is the board the cause?
It can be, since a single dead channel does not affect the rest. Check the sensor or solenoid first, then the plug, then the channel.

Q2: Two unrelated functions failed at once. What does that mean?
Look for a shared cause: supply voltage, a common connector, or moisture in the cabinet. That pattern is rarely two separate channel failures.

Q3: How can I tell a dead output from a dead solenoid?
Measure the coil resistance at the plug. A good coil with no response at the output points to the board.

Q4: Does the B2 version matter?
Yes. Channel assignment differs between versions, so a board of another version can leave functions dead even though it fits the connector.

Q5: How is the warranty handled?
Manufacturing defects are covered case by case. Damage from shorted solenoids, wrong supply voltage or static discharge is excluded.