BOARD MAIN I/O TOYOTA JAT-610 Air Jet Loom Part HL1157 YHE-0307 J9201-21010-00 B3 Output
Product Overview
Main I/O board, version B3, for Toyota JAT-610 / JAT-710 air jet looms. Original part number J9201-21010-00 B3, our item code YHE-0307, reference HL1157.
This board carries the output side of the loom: the solenoid and valve drivers that fire the nozzles, the relays and the stop motions. Output drivers do not usually fail on their own schedule - they fail because something on the field side shorted, or because the cabinet has been drawing in moisture and oil mist for years. Replacing the board without dealing with either cause puts the new one on the same path.
Applications & Compatibility
- Machine reference: JAT-610 / JAT-710
- Alternative model reference: JAT710 / JAT810
- Original part number: J9201-21010-00 B3
- Board version: B3
- Our item code: YHE-0307
- Reference: HL1157
Version B3 is quoted exactly as marked. Neighbouring versions of this board look identical and fit the same connector, so check the suffix on the old unit before ordering.
Protecting the Output Stage
- Measure valve coil resistance - a shorted coil is the most common killer of output drivers; compare every solenoid against the good ones on the loom.
- Dry the air supply - moisture carried in the pneumatic line reaches the valves and, from there, the cabinet.
- Check cabinet sealing and fan filter - oil mist conducts and corrodes; a blocked filter raises the internal temperature at the same time.
- Look for corrosion on the connector pins - green or black deposits mean the cabinet environment needs attention, not just the board.
If the failed channel shows a burned trace or a cracked driver device, treat it as evidence: find the shorted load before powering the replacement.
Quality Standard
- Board built to the B3 version, with the output channel plan kept identical to the original.
- Every output channel load tested, with current and temperature watched during run-in.
- Protection circuits verified for over-current response before packing.
- Conformal coating and terminal plating inspected, as this position sits in a dirty environment.
- Anti-static packaging with version label; store away from oil mist and humidity.
- Warranty against manufacturing defects, assessed case by case; damage from a shorted solenoid, moisture ingress, wrong supply voltage or static discharge during handling is not covered.

Specifications
| Product | Board, main I/O |
| Version | B3 |
| Original Part Number | J9201-21010-00 B3 |
| Item Code | YHE-0307 |
| Reference | HL1157 |
| Model | JAT710 / JAT810 |
| Machine | JAT-610 / JAT-710 |
| Function | Solenoid, valve and relay outputs with sensor inputs |
| Testing | Output load test and protection check |
| HS Code | 8448499000 |
| Place of Origin | Shanghai, China |
Order & Shipping Information
- Minimum order quantity: 1 piece.
- Sample order is acceptable for quality evaluation.
- Stock items ship within 5 working days after payment confirmation.
- Anti-static bag and foam protection in a neutral export carton.
- Shipping option: DHL / FedEx / UPS express, air freight, sea freight.
- Complete export documents including commercial invoice and packing list will be supplied.
- We ship worldwide to textile markets across Southeast Asia, Central Asia, South America, North America and Europe.

Frequently Asked Questions
Q1: How can I tell whether a solenoid or the output channel failed?
Measure the coil resistance at the plug. A coil within the normal range with no output response means the board; an open or shorted coil means the solenoid.
Q2: The same channel failed twice. What should I do?
Stop replacing and start measuring. A repeat failure at the same position almost always means a faulty load, chafed wire or moisture at that valve.
Q3: Is a conformal-coated board needed here?
It helps in a weaving shed, but it does not replace cabinet sealing and a clean air supply. Coating slows the damage, it does not stop it.
Q4: Can I swap this board with the B2 unit from another loom to test?
Only as a short diagnostic. Version differences can leave functions dead, so do not run production with a mismatched board.
Q5: How is the warranty handled?
Manufacturing defects are covered case by case. Damage from a shorted solenoid, moisture ingress, wrong supply voltage or static discharge is excluded.
Send your inquiry directly to us