BOARD MAIN I/O TOYOTA JAT-610 Air Jet Loom Spare Part HL1158 YHE-0308 J9201-21011-00 K3
Product Overview
Main I/O board, designation K3, for Toyota JAT-610 / JAT-710 air jet looms. Original part number J9201-21011-00 K3, our item code YHE-0308, reference HL1158.
Wrong stops are the fault this board is most often asked about. The input side reads warp stop motions, weft feelers, and the various proximity and photo sensors around the loom. When an input channel becomes slow, noisy or marginally sensitive, the loom stops for reasons nobody can see - and the operator blames the warp, the weft or the weather.
Applications & Compatibility
- Machine reference: JAT-610 / JAT-710
- Alternative model reference: JAT710 / JAT810
- Original part number: J9201-21011-00 K3
- Board designation: K3
- Our item code: YHE-0308
- Reference: HL1158
The designation K3 is part of the number, not a batch mark. Quote it with the enquiry so the correct variant is supplied.
Wrong Stops: Working Through the Inputs
- Note which stop appears - the panel message narrows the input group before any measuring starts.
- Check the sensor gap and cleanliness - lint on a photo sensor reads as a failed sensor, and a widened gap reads as an intermittent one.
- Inspect the screen and ground - unshielded sensor cable run beside an inverter output picks up noise and produces random stops.
- Compare with the neighbouring loom - the same signal on a second machine tells you whether the fault is in the board or in the field wiring.
- Look for a pattern in time - stops that cluster after a shift change or a wash-down point at moisture, not electronics.
A spare board is a valid test only after the field side has been checked. Fitting a board and finding the stops continue leaves you with two unknowns instead of one.
Quality Standard
- Board built to the K3 designation, with the input channel plan matching the original.
- Every input channel tested individually with a simulated sensor signal, including threshold behaviour.
- Input filtering and isolation verified, so noise rejection is as designed and not merely adequate.
- Output channels load tested; connector seating and plating inspected.
- Anti-static packaging with designation label for store control.
- Warranty against manufacturing defects, assessed case by case; damage from wrong supply voltage, shorted field wiring or static discharge during handling is not covered.

Specifications
| Product | Board, main I/O |
| Designation | K3 |
| Original Part Number | J9201-21011-00 K3 |
| Item Code | YHE-0308 |
| Reference | HL1158 |
| Model | JAT710 / JAT810 |
| Machine | JAT-610 / JAT-710 |
| Function | Sensor and stop motion inputs with solenoid outputs |
| Testing | Input threshold and output load test |
| HS Code | 8448499000 |
| Place of Origin | Shanghai, China |
Order & Shipping Information
- Minimum order quantity: 1 piece.
- Sample order is acceptable for quality evaluation.
- Stock items ship within 5 working days after payment confirmation.
- Anti-static bag and foam protection in a neutral export carton.
- Shipping option: DHL / FedEx / UPS express, air freight, sea freight.
- Complete export documents including commercial invoice and packing list will be supplied.
- We ship worldwide to textile markets across Southeast Asia, Central Asia, South America, North America and Europe.

Frequently Asked Questions
Q1: The loom stops at random with no fault visible. Where do I start?
Read the stop message and work through that input group: sensor gap, cleanliness, plug seating, then cable routing. Random stops rarely come from a single dead channel.
Q2: Could noise from the inverter cause this?
Yes, if sensor cable shares a duct with motor or inverter wiring. Separating the runs or restoring the screen often removes stops that no board replacement would fix.
Q3: How do I confirm the board is the cause?
Compare the same signal on a neighbouring loom, then test the channel with a known good sensor. If the field side is proven and the input still misreads, the board is the remaining suspect.
Q4: Does the K3 designation matter?
It does. This family shares the same outline, and the designation distinguishes variants with different input assignments.
Q5: How is the warranty handled?
Manufacturing defects are covered case by case. Damage from wrong supply voltage, shorted field wiring or static discharge is excluded.