CONTACTOR MAGNETIC PAK-20J TOYOTA JAT-710 JAT-810 Loom Part HL1164-2 Magnetic Switch
Product Overview
Magnetic contactor, type PAK-20J, for Toyota JAT-710 and JAT-810 air jet looms. Our reference HL1164-2.
In this family the model numbers are close enough to be misread: 12J, 20J and 21J sit on similar bodies with similar terminals. The 20J is not a variant of the 21J and not a larger 12J - each is a distinct rating. Reading the label carefully, and replacing the contactor in the right order, is what keeps a fifteen-minute job from becoming an afternoon of tracing wires.
Applications & Compatibility
- Machine reference: JAT-710 / JAT-810
- Contactor type: PAK-20J
- Our reference: HL1164-2
- Related types in this family: 12J, 21J - different ratings, not substitutes
Send a photo of the label on your old contactor with the enquiry. We confirm the type and coil voltage before dispatch, because both decide whether the replacement works.
Replacing a Contactor in the Right Order
- Isolate and prove dead - not just the main switch; check the control supply too.
- Photograph the wiring - a phone picture of the terminal arrangement saves more time than any drawing.
- Move one conductor at a time - transfer each wire from the old unit to the matching terminal before removing the next.
- Check the coil voltage before energising - confirm the marking on the new coil against the control circuit.
- Torque the terminals - loose power terminals overheat within weeks and take the new contacts with them.
- Test the sequence, not just the contactor - run the function and confirm direction and interlocks behave as before.
If the old contactor welded, look for the reason before fitting the new one: a jammed mechanism downstream or a load drawing more current than the rating will destroy the replacement too.
Quality Standard
- Contactor type and coil voltage verified against the ordered specification before dispatch.
- Contacts inspected for alignment and silver facing, with no pitting from test operations.
- Pick-up and drop-out tested at rated coil voltage, with armature travel checked.
- Arc chutes and spring pressure verified so interruption behaves as designed.
- Individual carton packing with type and coil voltage marked on the box.
- Warranty against manufacturing defects, assessed case by case; damage from a short circuit, wrong coil voltage, or welding caused by a downstream fault is not covered.

Specifications
| Product | Magnetic contactor |
| Type | PAK-20J |
| Reference | HL1164-2 |
| Model | JAT-710 / JAT-810 |
| Coil Voltage | Confirmed against the old unit before dispatch |
| Auxiliary Contacts | Matched to the original arrangement |
| Original Part Number | Not marked - quote by reference HL1164-2 |
| HS Code | 8448499000 |
| Place of Origin | Shanghai, China |
Order & Shipping Information
- Minimum order quantity: 5 pieces.
- Sample order is acceptable for quality evaluation.
- Stock items ship within 5 working days after payment confirmation.
- Individual carton with type and coil voltage marked; neutral export packing available.
- Shipping option: DHL / FedEx / UPS express, air freight, sea freight.
- Complete export documents including commercial invoice and packing list will be supplied.
- We ship worldwide to textile markets across Southeast Asia, Central Asia, South America, North America and Europe.

Frequently Asked Questions
Q1: How can I be sure the type is 20J and not 21J?
Read the moulded marking or label on the body, and photograph it before removal. The two differ in rating and should never be swapped on that assumption.
Q2: What if the label is unreadable?
Send a photo of the contactor with its terminal arrangement and the loom model. We compare it against the reference for that cabinet build.
Q3: Can I replace the contactor without a wiring diagram?
Yes, if you move one conductor at a time and photograph the arrangement first. Trying to rewire from memory rarely ends well.
Q4: The new contactor chatters. What is wrong?
Check the coil voltage first, then the control supply quality. Chattering is an electrical symptom, not a mechanical one, on a new unit.
Q5: How is the warranty handled?
Manufacturing defects are covered case by case. Damage from a short circuit, wrong coil voltage or a downstream fault is excluded.
Send your inquiry directly to us