CONTACTOR MAGNETIC S-N38 TOYOTA JAT-610 Air Jet Loom Part HL1165 YHE-0315 62313-01014
Product Overview
Magnetic contactor, type S-N38, for Toyota JAT-610 / JAT-710 air jet looms. Original part number 62313-01014, our item code YHE-0315, reference HL1165.
This contactor is usually paired with a thermal overload relay, and the pairing matters when something trips. The contactor switches; the relay protects. When a motor keeps dropping out, the relay is often doing its job correctly while the contactor is replaced for nothing - and the real cause, a rising current from a bearing or a jammed mechanism, stays in place.
Applications & Compatibility
- Machine reference: JAT-610 / JAT-710
- Alternative model reference: JAT710 / JAT810
- Contactor type: S-N38
- Original part number: 62313-01014
- Our item code: YHE-0315
- Reference: HL1165
Confirm the coil voltage marked on the old contactor. Coil voltage is not implied by the type designation and differs between cabinet builds.
Contactor or Overload Relay?
- A trip after a few minutes of running - typical of the overload relay responding to a real current rise; measure the current before touching the contactor.
- A trip immediately on start - suspect the relay setting, a short circuit, or a contactor pole that is not closing.
- Repeated trips with the same timing - the mechanism downstream is loading the motor; the relay is reporting the truth.
- No trip but the motor is hot - the relay setting may be too high for the motor. Protection that never acts is not protection.
Record the relay setting when you replace a contactor. Settings get disturbed during a swap and then nobody remembers what they were.
Quality Standard
- Contactor type and coil voltage verified against the ordered specification before dispatch.
- Contacts inspected for alignment and silver facing, with no pitting from test operations.
- Pick-up and drop-out tested at rated coil voltage with armature travel checked.
- Arc chutes and spring pressure verified so interruption behaves as designed.
- Individual carton packing with type and coil voltage marked on the box.
- Warranty against manufacturing defects, assessed case by case; damage from a short circuit, wrong coil voltage, or welding caused by an oversized load is not covered.

Specifications
| Product | Magnetic contactor |
| Type | S-N38 |
| Original Part Number | 62313-01014 |
| Item Code | YHE-0315 |
| Reference | HL1165 |
| Model | JAT710 / JAT810 |
| Machine | JAT-610 / JAT-710 |
| Coil Voltage | Confirmed against the old unit before dispatch |
| Associated Protection | Thermal overload relay, setting recorded at replacement |
| HS Code | 8448499000 |
| Place of Origin | Shanghai, China |
Order & Shipping Information
- Minimum order quantity: 5 pieces.
- Sample order is acceptable for quality evaluation.
- Stock items ship within 5 working days after payment confirmation.
- Individual carton with type and coil voltage marked; neutral export packing available.
- Shipping option: DHL / FedEx / UPS express, air freight, sea freight.
- Complete export documents including commercial invoice and packing list will be supplied.
- We ship worldwide to textile markets across Southeast Asia, Central Asia, South America, North America and Europe.

Frequently Asked Questions
Q1: Motor keeps tripping after a few minutes. Contactor or relay?
Measure the running current first. A rise above the relay setting points to the load, not the contactor. Replacing the contactor will not change the trip.
Q2: Can I use the old overload relay with the new contactor?
Usually yes, if the relay body and mounting match. Check the setting after fitting and confirm it against the motor nameplate.
Q3: How do I find the coil voltage?
It is printed on the coil or the contactor label. Photograph the old unit and quote it with your enquiry.
Q4: Can this contactor be fitted in place of the PAK type?
Only if the rating, coil voltage and mounting arrangement match the position. The designations belong to different families.
Q5: How is the warranty handled?
Manufacturing defects are covered case by case. Damage from a short circuit, wrong coil voltage or welding from an oversized load is excluded.
Send your inquiry directly to us