CONTACTOR MAGNETIC S-N48 TOYOTA JAT-810 Air Jet Loom Part HL1165-6 Motor Circuit
Product Overview
Magnetic contactor, type S-N48, for Toyota JAT-810 air jet looms. Our reference HL1165-6, item code HL1165-6.
This frame size sits on motor circuits, where the contactor takes the hardest duty in the cabinet. A motor draws several times its rated current for the first moments after start, and every one of those starts erodes the contact tips a little. That is why a motor contactor fails long before a control contactor of the same age - and why the motor itself should be checked before a replacement is fitted.
Applications & Compatibility
- Machine reference: JAT-810
- Contactor type: S-N48
- Our reference: HL1165-6
- Position: motor circuit in the loom electrical cabinet
Send a photo of the label on the old contactor with the enquiry so the type and coil voltage are confirmed before dispatch.
Motor Circuits: Check the Load First
- Measure the running current - compare it with the motor nameplate; a rise means load, not contactor.
- Watch the starting current - an unusually long or heavy start points at the mechanism the motor drives.
- Insulation test the motor - a winding failing to earth will destroy the new contactor in weeks.
- Check the overload relay setting - protection that has drifted leaves the contactor doing the protecting.
- Inspect the cable terminations - a loose lug on a motor circuit overheats and adds to the current the contacts must carry.
Starts per hour matter as much as the current. A motor contactor on a frequently cycled position wears through its tips on duty alone, and no brand changes that.
Quality Standard
- Contactor type and coil voltage verified against the ordered specification before dispatch.
- Contacts inspected for alignment and silver facing, with no pitting from test operations.
- Pick-up and drop-out tested at rated coil voltage with armature travel checked.
- Arc chutes and spring pressure verified, since motor loads place the heaviest demand on interruption.
- Individual carton packing with type and coil voltage marked on the box.
- Warranty against manufacturing defects, assessed case by case; damage from a short circuit, failing motor insulation, wrong coil voltage or welding caused by an oversized load is not covered.

Specifications
| Product | Magnetic contactor |
| Type | S-N48 |
| Reference | HL1165-6 |
| Item Code | HL1165-6 |
| Model | JAT-810 |
| Machine | JAT-810 |
| Position | Motor circuit |
| Coil Voltage | Confirmed against the old unit before dispatch |
| Original Part Number | Quote by reference HL1165-6 |
| HS Code | 8448499000 |
| Place of Origin | Shanghai, China |
Order & Shipping Information
- Minimum order quantity: 5 pieces.
- Sample order is acceptable for quality evaluation.
- Stock items ship within 5 working days after payment confirmation.
- Individual carton with type and coil voltage marked; neutral export packing available.
- Shipping option: DHL / FedEx / UPS express, air freight, sea freight.
- Complete export documents including commercial invoice and packing list will be supplied.
- We ship worldwide to textile markets across Southeast Asia, Central Asia, South America, North America and Europe.

Frequently Asked Questions
Q1: Why does the motor contactor wear out before the others?
Starting current. A motor draws several times its rated current at every start, and each start erodes the tips. Duty, not quality, sets the life.
Q2: What should I check before fitting a new one?
Motor insulation to earth, running and starting current, the overload relay setting and the cable lugs. Any of these can destroy a healthy contactor.
Q3: The contactor welds on start. What is the cause?
Usually an oversized load, a jammed mechanism or a motor with a failing winding drawing far above rating. Find the cause before fitting another.
Q4: Can I use a larger frame in its place?
Only if the coil voltage and mounting suit the position and the protection still matches the motor. Larger contacts do not replace correct protection.
Q5: How is the warranty handled?
Manufacturing defects are covered case by case. Damage from a short circuit, failing motor insulation, wrong coil voltage or an oversized load is excluded.
Send your inquiry directly to us