VALVE SENSOR TOYOTA JAT-810 Air Jet Loom Part HL1171-1 YHE-0318-1 Detector
Product Overview
Valve sensor for Toyota JAT-810 air jet looms. Item code YHE-0318-1, reference HL1171-1. Supplied against the reference; the original number is not marked on this item.
This sensor works with the valve on the same air circuit, and the pairing is what makes diagnosis difficult. When a pick goes missing, both parts are suspects and the panel reports one fault. The sensor exists to tell the control that the valve moved - so a sensor that lies looks exactly like a valve that did not move.
Applications & Compatibility
- Machine reference: JAT-810
- Our reference: HL1171-1
- Item code: YHE-0318-1
- Related item: valve, reference HL1171
- Function: sensing element associated with the valve position
The original number is not marked on the item, so please send a photograph of the old sensor with its connector and mounting bracket. We will match it by reference and confirm before invoicing.
Valve or Sensor? Splitting One Fault in Two
- Watch the sensor while the valve is operated by hand - switching at the sensor means the electronics are alive.
- Check the gap, not the appearance - mounting distance drifts as brackets settle and vibration works screws loose.
- Do not move the bracket to make it work - a shifted bracket hides a worn linkage and shifts the fault somewhere else.
- Inspect the cable where it flexes - a sensor that fails only while the loom runs is usually a broken strand, not a dead sensor.
- Separate air from electrics - operate the valve with air on and off, and watch the sensor independently of the spool.
- Never adjust the sensor to mask a slow valve - the timing error stays, and it ends up in the cloth.
Keep a known-good sensor for exactly this test. Swapping one in takes minutes and settles in a single step what an hour of guessing will not.
Quality Standard
- Item matched to reference HL1171-1 and to the supplied photograph before dispatch.
- Switching point and repeatability checked on test, not only presence or absence of a signal.
- Housing and cable gland inspected, since this position sees vibration and oil mist.
- Cable, connector and lead length verified against the original.
- Individual carton or anti-static bag with the reference marked.
- Warranty against manufacturing defects, assessed case by case; damage from a broken cable in service, incorrect gap setting, impact or fluid ingress is not covered.

Specifications
| Product | Valve sensor |
| Reference | HL1171-1 |
| Item Code | YHE-0318-1 |
| Model | JAT-810 |
| Machine | JAT-810 |
| Related Item | Valve, reference HL1171 |
| Function | Sensing element associated with the valve position |
| Original Part Number | Quote by reference HL1171-1 |
| HS Code | 9031809090 |
| Place of Origin | Shanghai, China |
Order & Shipping Information
- Minimum order quantity: 5 pieces.
- Sample order is acceptable for quality evaluation.
- Stock items ship within 5 working days after payment confirmation.
- Individual carton or anti-static bag with the reference marked; neutral export packing available.
- Shipping option: DHL / FedEx / UPS express, air freight, sea freight.
- Complete export documents including commercial invoice and packing list will be supplied.
- We ship worldwide to textile markets across Southeast Asia, Central Asia, South America, North America and Europe.

Frequently Asked Questions
Q1: How do I know whether the valve or the sensor failed?
Operate the valve by hand and watch the sensor. If the sensor switches, the valve is the suspect; if it does not, check the gap and the cable before replacing the sensor.
Q2: The sensor works when the loom is stopped but not when running. Why?
A cable with a broken strand, or a bracket that moves under vibration. Test it while the machine runs and flex the lead gently.
Q3: Can I adjust the gap to stop the alarm?
Only to the specified distance. Moving it further to silence an alarm hides a worn linkage, and the fault returns as a quality problem.
Q4: Why is there no original number on the item?
Many sensors in this position are not marked. A photograph of the old part with its connector and bracket identifies it reliably, and we confirm before shipping.
Q5: How is the warranty handled?
Manufacturing defects are covered case by case. Damage from a broken cable, incorrect gap setting, impact or fluid ingress is excluded.
Send your inquiry directly to us