logo

FP BOARD 12V TOYOTA JAT-710 Air Jet Loom Original Part HL1178 YHE-0324 J9206-02201-00

Place of Origin: Shanghai, China
Brand Name: Y&H China
Certification: Good Quality
Model Number: JAT-710
Product Details
Place of Origin:
Shanghai, China
Brand Name:
Y&H China
Certification:
Good Quality
Model Number:
JAT-710
Minimum Order Quantity:
1 Piece
Price:
Request a Quote
Standard Packaging:
Anti-static bag and foam protection in neutral export carton
Delivery Time:
5 working days for stock items
Payment Terms:
L/C, D/A, D/P, T/T
Specifications
Item Code:
YHE-0324
Original Part Number:
J9206-02201-00
Reference:
HL1178
Model:
JAT-710
Machine:
JAT-710
Product Type:
FP Board
Supply:
12 V DC
Position:
Front Panel Assembly
Testing:
Every Key And Indicator Tested Individually
Use:
Toyota JAT-710 Air Jet Looms
HS Code:
8448499000
Service:
24-Hour Online Service
Video Outgoing-Inspection:
Provided
Warranty:
Case-by-case
Key Markets:
Southeast Asia, Central Asia, South America, North America, Europe
Shipping:
Express (DHL/FedEx/UPS) / Sea Freight / Air Freight
Brand Name:
Y&H China
Product Description

Product Overview

FP board, 12 V, for Toyota JAT-710 air jet looms. Original part number J9206-02201-00, item code YHE-0324, reference HL1178. Original specification.

The front panel board is the one part of the control system that people touch. That makes its failures different from the rest of the cabinet: keys wear out, ribbons loosen, oil mist settles on the overlay, and the board gets replaced for problems that were never electronic. The 12 V supply it runs on is also the first thing to measure, because a panel that behaves oddly is often a panel being fed badly.

Applications & Compatibility

  • Machine reference: JAT-710
  • Original part number: J9206-02201-00
  • Our item code: YHE-0324
  • Reference: HL1178
  • Supply: 12 V DC
  • Position: front panel assembly

Confirm the original number and the connector arrangement before ordering. Panel assemblies differ between build years even where the layout looks the same.

When the Panel Is Not the Fault

  • Measure the 12 V rail at the panel - not at the supply. A drop along the cable shows up as a panel that misbehaves only when the loom is busy.
  • Test the keys one by one - a single dead key is a worn contact, not a dead board.
  • Reseat the ribbon before replacing anything - a loosened connector produces exactly the symptom of a failed panel.
  • Look at the overlay - oil mist and fibre under a worn overlay press on keys continuously.
  • Check that it is not the machine - a panel that freezes only during a specific operation is being asked to do something the loom cannot.

One dead segment on a display and a completely blank panel are different faults. Reporting which one you have shortens the diagnosis more than any description of the loom.

Cleaning It Without Killing It

  • No solvents on the overlay - they cloud the window and soften the printed layers.
  • Damp cloth, not wet - liquid at the edge of the overlay is how moisture reaches the board behind it.
  • Wipe, do not press - pressure on a membrane key is what wears it out.
  • Keep the panel covered during washing down - the loom gets cleaned far more often than the panel gets serviced.
  • Do not use sharp tools at the edges - a lifted overlay lets oil straight onto the contacts.

Most panels that fail early were cleaned aggressively. The ones that last are wiped gently and kept dry, which costs nothing.

Quality Standard

  • Board supplied to the original part number with the correct connector layout and revision.
  • Every key and indicator tested individually on the bench, with results recorded.
  • Display and backlight checked for uniform output and absence of dead segments.
  • Verified operation across the specified 12 V range, including the low end.
  • Anti-static bag and foam packing with the reference and original number marked; serial recorded.
  • Warranty against manufacturing defects, assessed case by case; damage from liquid ingress, solvent cleaning, physical impact, wrong supply voltage or static discharge during handling is not covered.

Air jet loom spare part quality inspection and stability test

Specifications

ProductFP board
Original Part NumberJ9206-02201-00
Item CodeYHE-0324
ReferenceHL1178
ModelJAT-710
MachineJAT-710
Supply12 V DC
PositionFront panel assembly
TestingEvery key and indicator tested individually
HS Code8448499000
Place of OriginShanghai, China

Order & Shipping Information

  • Minimum order quantity: 1 piece.
  • Sample order is acceptable for quality evaluation.
  • Stock items ship within 5 working days after payment confirmation.
  • Anti-static bag and foam protection in a neutral export carton.
  • Shipping option: DHL / FedEx / UPS express, air freight, sea freight.
  • Complete export documents including commercial invoice and packing list will be supplied.
  • We ship worldwide to textile markets across Southeast Asia, Central Asia, South America, North America and Europe.

Air jet loom spare part export packing and shipping

Frequently Asked Questions

Q1: One key does not respond. Do I need a whole board?
Not necessarily. A single key is usually a worn contact or a dirty membrane. Test the others before deciding; a board with one dead key is a candidate for replacement, not the first suspect.

Q2: The panel freezes only when the loom is running. Why?
Measure the 12 V at the panel while it happens. A voltage that sags under load makes a healthy panel misbehave exactly like a faulty one.

Q3: The display has one dark segment. Can that be repaired?
A single segment points at the display or its driver rather than the whole board. Report it precisely - it changes which part is needed.

Q4: How should I clean the panel?
A damp cloth, wiped gently, no solvents and no pressure on the keys. Keep it covered during wash-down of the loom.

Q5: How is the warranty handled?
Manufacturing defects are covered case by case. Damage from liquid ingress, solvent cleaning, impact, wrong supply voltage or static discharge is excluded.

Send your inquiry directly to us