JAT810 MAIN MOTOR 2.6KW Toyota Air Jet Loom Drive Motor 61210-33047 Part HL1244 Replacement
Product Overview
Main drive motor, 2.6 kW, for the Toyota JAT810 air jet loom, supplied to original part number 61210-33047 under our item code HL1244. The motor carries the main shaft of the loom through the drive train, so it runs continuously at production speed and is one of the first parts to show the effect of heat, dust and belt tension.
Replacing a main motor is not a difficult job, but it is an unforgiving one. Alignment, belt tension and rotation direction are all set during installation, and any of the three being slightly off turns a new motor into a hot motor within a few weeks. The notes below are written for the electrician and the mechanical fitter working together, which is how this job is normally done.
Applications & Compatibility
- Application: main drive of the Toyota JAT810 air jet loom
- Machine model: JAT810
- Rated power: 2.6 kW
- Original part number: 61210-33047
- Our item code: HL1244
- Supplied as: motor unit as listed, ready for installation with your existing pulley and coupling
Please confirm the original part number and the machine model when ordering. Toyota used more than one main motor rating across the JAT generation, and a motor that is physically identical can differ in rating, winding or shaft detail. Send the nameplate details of the motor being replaced together with a photograph, and we check them before quoting.
Before You Energise a New Main Motor
- Alignment first - check the pulley and coupling alignment with a straight edge or dial gauge; misalignment shows up as vibration long before it shows up as heat.
- Belt tension by the book - an over-tightened belt loads the bearings and the motor shaft; a loose belt slips and glazes.
- Rotation direction - confirm the direction of rotation before coupling the loom, not after.
- Insulation resistance - measure before connecting; a motor that has stood in a humid warehouse can read low until it is dried.
- Terminal condition - inspect cable lugs and terminal box; a loose lug on a 2.6 kW drive is a common cause of a "new motor" that trips.
- Cooling path - clean the fan cover and the air path around the motor; lint on the fins is the most common reason a motor runs hot in a weaving shed.
- Record the settings - note the inverter parameters and any speed references before removal, so the loom restarts from known values.
Most motor complaints in a weaving mill are installation or environment complaints rather than winding failures. The checks above take under an hour and prevent most repeat visits.
Signs the Motor Is the Fault
- Heat that does not follow the load - a motor running hot on light load is usually a winding, bearing or cooling problem, not a production issue.
- Current imbalance between phases - measured at the terminals under the same load; an imbalance points at the winding.
- Noise that changes with speed but not with load - typically bearings rather than winding.
- Trips that repeat at the same point in the cycle - check the drive and the mechanical load before replacing the motor.
- Vibration after a belt change - alignment and tension, not the motor.
Where a motor is suspected, isolate the drive and compare the readings with a known good machine of the same model. That comparison is worth more than any single measurement taken on its own.
Quality Standard
- Motor identity verified against original part number 61210-33047 and our item code HL1244 before packing.
- Nameplate rating, shaft dimensions and mounting dimensions checked against the original specification.
- Insulation resistance measured and recorded before shipment.
- No-load run test where test facilities apply; vibration and bearing noise checked by hand and by ear.
- Shaft, keyway and terminal box inspected; no rust on the shaft, no damaged terminal studs.
- Packed in a reinforced export carton with the shaft protected and the motor immobilised.
- Video outgoing inspection can be provided on request before shipment.
- Warranty covers manufacturing defects, assessed case by case. Damage caused by incorrect installation, misalignment, over-tensioned belts, incorrect supply voltage, inverter faults, moisture ingress or impact is excluded.

Specifications
| Product | Main motor |
| Item Code | HL1244 |
| Original Part Number | 61210-33047 |
| Rated Power | 2.6 kW |
| Machine Model | JAT810 |
| Application | Main drive, Toyota JAT810 air jet loom |
| Voltage / Frequency | As per original specification; confirmed per enquiry for your mill supply |
| Testing | Insulation resistance measured; dimensions checked; no-load run test where facilities apply |
| HS Code | 8501520000 |
| Place of Origin | Shanghai, China |
Order & Shipping Information
- Minimum order quantity: 1 piece.
- Sample order is not applicable for this item; single-unit orders are accepted.
- Stock items ship within 5 working days after payment confirmation.
- Reinforced export carton with the shaft protected and the motor immobilised; private-label packaging available on request.
- Shipping option: DHL / FedEx / UPS express, air freight, sea freight. Motors are normally shipped by air or sea freight because of weight.
- Complete export documents including commercial invoice and packing list will be supplied.
- We ship worldwide to textile markets across Southeast Asia, Central Asia, South America, North America and Europe.

Frequently Asked Questions
Q1: Is this motor a direct replacement for 61210-33047 on a JAT810?
Yes, it is supplied to that original part number for the JAT810 main drive. Send the nameplate details of the old motor and we confirm the match before quoting.
Q2: Can you confirm the voltage and frequency for my mill?
Send your mill supply specification with the enquiry. The motor is quoted against the original specification and we confirm the rating before shipment.
Q3: Do I need to change the pulley or coupling?
Normally no. The existing pulley and coupling are reused; check alignment and belt tension after fitting.
Q4: What causes a new motor to run hot?
Misalignment, over-tightened belts, blocked cooling fins, incorrect inverter settings and loose terminal connections are the usual causes, in that order.
Q5: What about the warranty?
Manufacturing defects are covered case by case. Damage from incorrect installation, misalignment, incorrect supply voltage, inverter faults, moisture or impact is not covered.
Send your inquiry directly to us